搜索
 
       

Bently3500

  本特利振动监测

本特利26530双探头传感器系统

 本特利26530双探头传感器系统
26530 Dual Probe Transducer System
The Dual Probe Transducer System consists of a proximity probe and aseismic or Velomitor® transducer installed at approximately the samepoint in a common transducer housing. This transducer system iscapable of making four separate measurements:
1、 Shaft relative radial position (displacement) relative to the probemounting location, measured by the proximity probe;
2、 Shaft relative radial dynamic motion (vibration) relative to theprobe mounting location, measured by the proximity probe;
3、 Machine casing absolute vibration measured by the seismicvibration; and
4、 Shaft absolute motion represented by the summation of theseismic signal (after integration to displacement) and the shaftrelative displacement.
The Dual Probe Transducer System provides the its best measurementdata when transducer housing is mounted on a portion of the bearinghousing or cover that is mechanically referenced to the bearing.For complete machinery monitoring diagnostics using orbit analysis andshaft centerline position information, two Dual Probe assemblies in anX-Y configuration are required per radial bearing.
选型方式
26530-AXX-BXX-CXX-DXXX-EXXX-FXX-GXX-HXX
Option Descriptions
A: Proximity Probe
Option
0 0 Probe not required
1 2 3300 XL 8 mm Probe
1 3 70000-series Radiation Resistant 300 Probe
1 8 3300 XL 8 mm Probe, Multiple Approvals
2 6 3300 NSv Probe
2 7 3300 NSv Probe, Multiple Approvals
2 9 3300 XL 11 mm Probe
3 0 3300 XL 11 mm Probe,
Multiple Approvals
B: Probe Lead Length Option
0 0 Probe not required
0 5 0.5 metre
1 0 1.0 metre
C: Adapter Thread
Option
0 0 Adapter not required
0 1 7/8-14 UNF
0 2 1-11 1/2 NPT
0 3 3/4-14 NPT
D: Adapter Length
Option
Order in increments of 0.1 in (2.5 mm).
Minimum length: 1.7 in = 0 1 7
(43 mm) [1.8 in if adapter thread
option is C: -03]
Maximum length: 2.0 in = 0 2 0
E: Probe Penetration
Option
Order in increments of 0.1 in (2.5 mm).
Minimum length: 1.0 in = 0 1 0 (25 mm)
For 0.5 metre probe cable on 3300
Probes:
Maximum length of "D" + "E" is
15.6 in = 1 5 6 (396 mm).
For 1.0 metre probe cable:
Maximum length of "D" + "E" is
31.0 in = 3 1 0 (787 mm).
Note: For penetration lengths between 1.0and 2.0 inches, counter bore may be requiredin machine case to reduce probe side viewand/or rear view effects. 1.0-1.9 inchpenetration lengths not available with 3300

现价:
¥ 0.00
创建时间:2016-08-28 08:07